Tripp Lite SmartOnline 3kVA
New
Tripp Lite SmartOnline 3kVA. Output power capacity (VA): 3000 VA Output power: 2400W Input operation voltage (min): 110V. AC outlet types: NEMA 5–15R NEMA 5–20R NEMA L5-30R Power plug: NEMA L5-30P Cable length: 118.1" (3m). Typical backup time at half load: 14 min Typical backup time at full load: 5 min. Form factor: Rackmount/Tower Color of product: Black. UPS topology: Double-conversion (Online)
$1,822.62 |
Extended Warrenty
1 Year Extended Warrenty | $91.13 |
You may be also interested
3000VA on-line double-conversion UPS system for critical server network and telecommunications equipment. 3U rackmount form factor with an installed depth of 26 inches. Expandable battery runtime with optional BP72V15-2U (limit 1) BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs. Full time sine wave 110 or 120V output with +/-2% voltage regulation. Online double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC then re-converts output back to completely regulated filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 150V. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. NEMA L5-30P input plug. NEMA 5-15 NEMA 5-15/20R and NEMA L5-30R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB port DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU switching supports load shedding and remote reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs. LED display panel easily rotates for viewing in rackmount or tower configurations. Dataline surge suppression for dialup DSL or network Ethernet connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITHD 2-post rackmount accessories available. Field-replaceable hot-swappable internal batteries and external battery packs. Attractive all-black color scheme. $250000 Ultimate Lifetime Insurance (U.S. Canada and Puerto Rico only).
- SmartOnline high performance UPS system is ideal for critical voice data medical and industrial network applications
- True on-line double-conversion UPS provides perfectly regulated sine wave output within 2% of 110/120V (user selectable) under all usage conditions
- Maintains continuous operation through blackouts voltage fluctuations and surges with zero transfer time
- Highly efficient operation in optional economy mode setting saving BTU heat output and energy costs
- Removes harmonic distortion fast electrical impulses frequency variations and other hard to solve power problems not addressed by other UPS types
- Corrects line voltage conditions as low as 65V and as high as 150V back to selectable 110/120V (+/-2%) values
- Standard internal battery set offers 14 minutes runtime at half load (1200W) and 5 minutes at full load (2400W)
- Expandable battery runtime with optional BP72V15-2U (limit 1) BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs
- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
- Compact rackmount form factor installs using only 3 rack spaces (3U) with a maximum installed depth of 26 inches
- Ships with all mounting accessories for 4 post rackmount installation
- Optional 2POSTRMKITHD enables 2 post rackmount installation (not wallmount compatible)
- Optional 2-9USTAND accessory enables small-footprint upright tower placement
- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
- Network interfaces support simultaneous communications via built-in USB DB9 serial / contact-closure and SNMPWEBCARD slot
- HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
- Included PowerAlert UPS monitoring software supports safe unattended shutdown monitoring and control via local connected servers plus any number of additional servers over IP
- UPS interface supports on-battery low-battery power-restored AC-voltage DC-voltage output current monitoring battery charge current battery capacity AC line frequency timed inverter shutoff activate self-test load bank output power control and remote reboot UPS nominal voltage adjustment and UPS line to battery power voltage setpoints
- Built-in Emergency Power Off (EPO) interface with cable
- NEMA L5-30P input plug; NEMA 5-15/20R & L5-30R output receptacles
- Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each bank has four outlets)
- Front panel LEDs offer current monitoring and battery charge level information
- UPS ships fully assembled in full compliance with DOT regulations; no time consuming connection of internal batteries by user required
- Single line TEL/DSL or network ethernet line surge suppression
- $250000 Ultimate Lifetime Insurance (U.S. Canada and Puerto Rico only)
- SmartOnline high performance UPS system is ideal for critical voice data medical and industrial network applications
- True on-line double-conversion UPS provides perfectly regulated sine wave output within 2% of 110/120V (user selectable) under all usage conditions
- Maintains continuous operation through blackouts voltage fluctuations and surges with zero transfer time
- Highly efficient operation in optional economy mode setting saving BTU heat output and energy costs
- Removes harmonic distortion fast electrical impulses frequency variations and other hard to solve power problems not addressed by other UPS types
- Corrects line voltage conditions as low as 65V and as high as 150V back to selectable 110/120V (+/-2%) values
- Standard internal battery set offers 14 minutes runtime at half load (1200W) and 5 minutes at full load (2400W)
- Expandable battery runtime with optional BP72V15-2U (limit 1) BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs
- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
- Compact rackmount form factor installs using only 3 rack spaces (3U) with a maximum installed depth of 26 inches
- Ships with all mounting accessories for 4 post rackmount installation
- Optional 2POSTRMKITHD enables 2 post rackmount installation (not wallmount compatible)
- Optional 2-9USTAND accessory enables small-footprint upright tower placement
- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
- Network interfaces support simultaneous communications via built-in USB DB9 serial / contact-closure and SNMPWEBCARD slot
- HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
- Included PowerAlert UPS monitoring software supports safe unattended shutdown monitoring and control via local connected servers plus any number of additional servers over IP
- UPS interface supports on-battery low-battery power-restored AC-voltage DC-voltage output current monitoring battery charge current battery capacity AC line frequency timed inverter shutoff activate self-test load bank output power control and remote reboot UPS nominal voltage adjustment and UPS line to battery power voltage setpoints
- Built-in Emergency Power Off (EPO) interface with cable
- NEMA L5-30P input plug; NEMA 5-15/20R & L5-30R output receptacles
- Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each bank has four outlets)
- Front panel LEDs offer current monitoring and battery charge level information
- UPS ships fully assembled in full compliance with DOT regulations; no time consuming connection of internal batteries by user required
- Single line TEL/DSL or network ethernet line surge suppression
- $250000 Ultimate Lifetime Insurance (U.S. Canada and Puerto Rico only)
Product Specifications
AC outlet types | NEMA 5–15R NEMA 5–20R NEMA L5-30R |
Cable length | 3 |
Certification | UL1778 (USA) CSA C22.2 No. 107.3 (Canada) NOM (Mexico) Class A FCC Part 68 / Industry Canada RoHS. |
Color of product | Black |
Depth | 660 |
Form factor | Rackmount/Tower |
Height | 133 |
Input connection type | NEMA L5-30P |
Input operation voltage (max) | 120 |
Input operation voltage (min) | 110 |
Operating relative humidity range | 0 - 95 |
Operating temperature range (T-T) | 0 - 40 |
Output on PDU sticks | 9 |
Output power | 2400 |
Output power capacity (VA) | 3000 |
Package depth | 800 |
Package height | 286 |
Package weight | 51000 |
Package width | 584 |
Power plug | NEMA L5-30P |
Power supply input frequency | 50/60 |
RoHS compliance | Y |
Storage temperature range (T-T) | -15 - 50 |
Surge energy rating | 480 |
Typical backup time at full load | 5 |
Typical backup time at half load | 14 |
UPS topology | Double-conversion (Online) |
Weight | 33500 |
Width | 451 |
Material Safety Data Sheet
A Material Safety Data Sheet (MSDS) is a document that contains information on the potential hazards (health, fire, reactivity and environmental) and how to work safely with the chemical product.
Sorry this product does not have any reviews at this time.